SvcPacketEntities
Part of Net/Svc message.
| Name | Type | Size in bytes | Size in bits | Value | 
|---|---|---|---|---|
| MaxEntries | int | 1.375 | 11 | - | 
| IsDelta | bool | 0.125 | 1 | - | 
| DeltaFrom¹ | int | 4 | 32 | - | 
| BaseLine | boolean | 0.125 | 1 | - | 
| UpdatedEntries | int | 1.375 | 11 | - | 
| Length | int | 2.5 | 20 | - | 
| UpdateBaseline | bool | 0.125 | 1 | - | 
| Data | byte[] | Length / 8 | Length | - | 
¹ Depends if the IsDelta bit is set.
Pseudocode Example
let max_entries = read_bits(11);
let is_delta = read_one_bit();
if is_delta {
    let delta_from = read_int32();
}
let baseLine = read_one_bit();
let updated_entries = read_bits(11);
let length = read_bits(20);
let update_baseline = read_one_bit();
let data = read_bits(length);